Model ASP 5,5
Type ASP 5,5
Splitting force 55 kN (5.5 t) ± 10 %
Log length max. 1050 mm
Log diameter min. 100 – max. 300 mm
Stroke
≈ 500 mm
Feed speed ca. 0,06 m/sec.
Return speed ca. 0,13 m/sec.
Hydraulic oil (max.) 4,0 litres
Hydraulic pressure 20 MPa (200 bar)
Electric motor performance (power consumption) AC P
1
= 3500 W (S6-40%)
Threephase P
1
= 3000 W (S6-40%)
Power supply AC 230 V ~ 50 Hz, 16 A inert
Threephase 400 V 3~ 50 Hz, 16 A
Dimensions Length 740 x Width 500 x Height 1520 mm
Weight ca. 96 kg
P
P
o
o
s
s
s
s
i
i
b
b
l
l
e
e
p
p
r
r
o
o
b
b
l
l
e
e
m
m
s
s
Problem possible cause remedy
Logs are not being split properly
(insufficient splitting performance)
⇒ The log is not positioned correctly
⇒ The log exceeds the maximum dimensions
or the wood is too hard for the
performance of the machine
⇒ Splitting blade does not split log
⇒ Hydraulic pressure too low
⇒ Release rods bent (hydraulic tappet not
quite pressed in)
⇒ Incorrect connecting lead (longer than 10
m or too small cable cross-section)
⇒ Reposition the log correctly
⇒ Cut the log to the required dimensions
⇒ Sharpen splitting blade, check for burrs or
notches
⇒ Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒ Arrange for manufacturer or authorised company
to adjust the rods
⇒ Use the correct connecting lead
Splitting column moves unsteadily
or with strong vibrations
⇒ Air in the circuit
⇒ Splitting column not sufficiently lubricated
or oiled.
⇒ Check the oil level and add more oil if necessary.
⇒ Lubricate splitting column or oil with
environmentally friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not move
⇒ Hydraulic pump defective ⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
Motor starts up but splitting
column does not move
⇒ Motor turns in wrong direction ⇒ Check the motor direction
Threephase: adjust the motor direction (s. page
18)
AC: To correct the problem, refer to the manu-
facturer or other approved service centre.
Motor will not start
⇒ No electrical power
⇒ 2-phase mode in threephase motor
⇒ Connection cable defective
⇒ Electric motor defective
⇒ Check the fuse.
⇒ Have fuse and lead checked by qualified
electrician.
⇒ Replace the connection cable or have it checked
by an electrician.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.